SC-1 Quick Reference Guide (OS fi rmware version 3) by Draper
This Sheet uses # for the receiver’s main channel number - new units will use a 1 where # is.
Note that # can also be ALL if you want to program several receivers S = Stop C = Close 0 = Open
LED on blink blink off
Reset EVERYTHING to factory default S+7+7 O ALL hold 5 sec. until blink S
Reset everything except main channel to factory default S+7+7 O # C ALL S
Main Channel to “N”ew channel (N = 1 through 59), S+7+7 O # C 1 O “N” S
1ST Group Channel to “N”ew channel (N = 1 through 60) S+7+7 O # C 2 O “N” S
1ST Group Channel OFF S+7+7 O # C 2 O ALL S
Set 2ND Group Channel (same as above) S+7+7 O # C 3 O “N” S
Set 3RD Group Channel (same as above) S+7+7 O # C 4 O “N” S
Set 4TH Group Channel (same as above) S+7+7 O # C 5 O “N” S
Set 5TH Group Channel (same as above) S+7+7 O # C 13 O “N” S
Set 6TH Group Channel (same as above) S+7+7 O # C 14 O “N” S
Set “Sequential Action” Channel (same as above) S+7+7 O # C 20 O “N” S
Set “Specifi c Stop” Channel (same as above) S+7+7 O # C 22 O “N” S
Reset the following options to factory default S+7+7 O # C 6 O ALL S
Momentary Motor Action S+7+7 O # C 6 O 1 S
Reverse Motor Direction S+7+7 O # C 6 O 2 S
Do NOT Act on ALL buttons from Transmitter S+7+7 O # C 6 O 3 S
Stop On Transmitter Button Release S+7+7 O # C 6 O 8 S
Disable the Deadbeat Counter S+7+7 O # C 6 O 11 S
Enable the Deadbeat Counter, and reset it to 120 S+7+7 O # C 6 O 12 S
Reset the following options to factory default S+7+7 O # C 7 O ALL S
SPST Manual switch S+7+7 O # C 7 O 1 S
Stop On SPDT Manual Switch Release S+7+7 O # C 7 O 3 S
Swap Open and Close on SPDT, Invert SPST S+7+7 O # C 7 O 5 S
Enable SPST Magnetic Switch as Override S+7+7 O # C 7 O 6 S
Turn off all “A” intermediate stops (factory default) S+7+7 O # C 10 O ALL S
Enable “Intermediate Stop A” on the main channel S+7+7 O # C 10 O 1 S
Enable “Int. Stop A” on 1ST group channel S+7+7 O # C 10 O 2 S
Enable “Int. Stop A” on 2ND group channel S+7+7 O # C 10 O 3 S
Enable “Int. Stop A” on 3RD group channel S+7+7 O # C 10 O 4 S
Enable “Int. Stop A” on 4TH group channel S+7+7 O # C 10 O 5 S
Enable “Int. Stop A” on 5TH group channel S+7+7 O # C 10 O 6 S
Enable “Int. Stop A” on 6TH group channel S+7+7 O # C 10 O 14 S
Enable “Int. Stop A” on the ALL channel S+7+7 O # C 10 O 7 S
Enable “Int. Stop A” on Manual Switches S+7+7 O # C 10 O 8 S
Calibrate the travel times **Required for using Int. Stop A or B** S+7+7 O # C 10 O 10 **
Reference the bottom (close limit) instead of top (open) S+7+7 O # C 10 O 11 S
(if both A & B stops are set on a channel, A takes precedence)
“Intermediate Stop A Open Button,” default is 20% closed
Set to 10x+y percent of travel time away from reference end S+7+7 O # C 11 Ox Oy S
min = 0 0 (at ref.), max = 9 9 (opposite limit) use O10 for 0
“Intermediate Stop A Close Button,” default is 80% closed S+7+7 O # C 12 Ox Oy S
Turn off all “B” Intermediate stops (factory default) S+7+7 O # C 15 O All S
Enable “intermediate Stop B” on the main channel S+7+7 O # C 15 O 1 S
Enable “Int. Stop B” on 1ST group channel S+7+7 O # C 15 O 2 S
Enable “Int. Stop B” on 2ND group channel S+7+7 O # C 15 O 3 S
Enable “Int. Stop B” on 3RD group channel S+7+7 O # C 15 O 4 S
Enable “Int. Stop B” on 4TH group channel S+7+7 O # C 15 O 5 S
Enable “Int. Stop B” on 5TH group channel S+7+7 O # C 15 O 6 S
Enable “Int. Stop B” on 6TH group channel S+7+7 O # C 15 O 14 S
Enable “Int. Stop B” on the ALL channel S+7+7 O # C 15 O 7 S
Enable “Int. Stop B” on Manual Switches S+7+7 O # C 15 O 8 S
(if both A & B stops are set on a channel, A takes precedence)
“Intermediate Stop B Open Button,” default is 40% closed S+7+7 O # C 16 Ox Oy S
“Intermediate Stop B Close Button,” default is 60% closed S+7+7 O # C 17 Ox Oy S
** There is no Stop button press at the end of the calibration command. Calibration required for Int. Stops to work.**
®
Copyright © 2008 Draper Inc. Form DraperSC1QuickReferenceGuide_08 Printed in U.S.A.