Please Note
➀ Make sure power is disconnected before installing controls.
➁ SPGC4 is a line voltage control, designed to individually operate 4
motors, activated by Low Voltage input commands.
➂ SPGC4 enclosure is 8" x 8" x 4".
➃ The Main Disconnect and Branch Circuit Protection shall be provided by
installer.
➄ Maximum surrounding air temperature 50° C.
➅ Use copper conductors rated 75 degrees Celsius or higher only, 18-
12AWG.
Please Note: This device has not been evaluated for reliability to the
Standard for Tests for Safety-Related Controls Employing Solid-State
Devices, UL 991 and therefore not considered suitable for entrapment
protection.
Wiring Instructions
™
SPGC4 Control by Draper
If you encounter any diffi culties installing/wiring your IntelliFlex control, call your dealer or
Draper, Inc., Spiceland, Ind., (765) 987-7999; or fax (765) 987-7142.
Part Number C156.060
Inserting wire into spring terminal
➀ Open spring terminal by inserting screw-
driver into upper opening.
➁ Insert wire into lower opening.
➂ Remove screwdriver.
Electrical Specifi cations
Input:
Data: +5v AC BUS Commands
Low Voltage: Dry Contact—0v AC
Line Voltage: 115v AC +/- 10%
Output:
115VAC Largest Motor 1FLA, 4FLA Total
E258229
Please Note: Connect Ground
wires as noted on enclosure
IntelliFlex
To
Eye
Port
To Switch,
splitter or
other input
device
IntelliFlex
Neutral
AC (115V AC)
IntelliFlex
IntelliFlex
Data cable
from Aux Port
to Eye port of
next SPGC4
Aux
Port
Aux
Port
Aux
Port
Aux
Port
Eye
Port
Eye
Port
Dry
Contacts
Dry
Contacts
Dry
Contacts
To
Motor
To
Motor
To
Motor
Black (Dir)
Red (Dir)
Neutral
Neutral
Red (Dir)
Black (Dir)
Neutral
Red (Dir)
Black (Dir)
To
Motor
Black (Dir)
Red (Dir)
Neutral
Please Note:
Connect all
Ground wires to
ground block
provided.
Eye
Port
Max of 100 feet
of cable
between
controls, or
control and
input with
circuit
board.
Fabric un roll ing from back of
roller (standard)
Fabric unrolling from front of
roller (reverse roll)
Interior
side
Interior
side
Right hand motor
(Standard)
Black—Up
Red—Down
Left hand motor
Black—Down
Red—Up
Right hand motor
(Standard)
Red—Up
Black—Down
Left hand motor
Red—Down
Black—Up
All connection wires must conform to the motor manufacturer’s
recommendation and prevailing electrical codes. The switch and control
system wires should be at least 24 AWG and no larger than 18 AWG.
Please Note:
All input devices (low voltage LED switches, IR eye, RF receiver) which
connect to the Eye jack must be connected using electrically straight 4-
conductor modular cable (RJ11). This means colors do not cross over: blue
leads to blue, orange to orange, etc. (see diagram below)
If you use standard telephone cable, you must fi rst remove one connector,
turn it over and re-attach, to ensure that the cable is electrically straight (see
diagram below). Standard phone cable is 26 AWG.
Yellow
Red
Green
Black
Yellow
Red
Green
Black
Yellow
Green
Red
Black
Yellow
Green
Red
Black
Standard Telephone Cable
(Before, will not work)
Telephone Cable After
(Electrically Straight-will work)
Yellow
Green
Red
Black
Yellow
Green
Red
Black
Electrically Straight Data Cable