Input Device Sample Confi guration
™ by Draper
Copyright ©2007 Draper Inc. Form IntelliFlex-InputDeviceConfi g07 Printed in U.S.A.
Notes on Power Consumption:
Any input device may be connected to any available Eye port.
All Eye ports are "powered" by the "SC1" they feed off of. Each
SC1 Eye port provides 75 milliAmps at 5v of power to the connect-
ed input devices. You may attach any combination of input devices
to an SC1 Eye port, as long as the combined power requirements
do not exceed the available power from the SC1 (see chart below).
Notes on Cable Lengths:
You can have a total of approximately 100 feet of
cable between SC1s, up to a maximum of 1000 feet.
However, any device that includes a Repeater can
drive 1000 feet of cable regardless.
IR Eyes have no circuit board and can only drive
about 20' of cable.
Input Device Power Consumption Chart
Input Device
1
Power Consumption (milliAmps)
RF Remote Receiver 17
IR Receiver Eye 2
Sun Sensor 13
IntelliFlex Bus Switch 8
IntelliFlex RF Switch (not on Bus) 0
IntelliFlex Dry Contact Switch (not on Bus) 0
PSI60 9
R2D7 (RS232 Translator) 17
Hardwired Keypad 1
RF Keypad (not on Bus) 0
1
IR Eye can drive a maximum of 25 SC1s. Other accessories can drive a maximum of 70 SC1s.
Please Note:
Wiring diagrams are available for each control
and input device at www.draperinc.com.
Eye
Eye
Main
Aux
SC1,
SPGC4
or SGC4
SC1,
SPGC4
or SGC4
SC1,
SPGC4
or SGC4
Eye
Eye
Main
Aux
3
5
7
4
6
8
Sun
Sensor
To "Eye"
Port
(+75mA)
From "Aux"
To "Aux"
(can also
be "Aux to Eye")*
From "Aux"
To "Eye"*
To "Eye" Port
Eye
Eye
Main
Aux
R2D7
IR
Receiving
Eye (-2 mA)
RR24 RF
Receiver
SC1,
SPGC4
or SGC4
From "Aux"
To "Aux"
(can also be
"Eye to Aux"
if "Eye" port
not in use)*
Eye
Eye
Main
Aux
To "Eye" Port
1 sample "Bus" System shown (motors on line voltage side). Multiple "Systems" may be combined and "linked" in an installation.
SC1,
SPGC4
or SGC4
PSI
60
SPDT:
Keyswitch,
Mag. switch,
etc.
Splitter
Splitter
Splitter
Splitter
To Motor (s)
To Motor (s)
To Motor (s)
To Motor (s)
To Motor (s)
SC1,
SPGC4
or SGC4
From "Aux" To "Aux"
(can also be "Eye to Aux"
if Eye port is not in use)*
To Motor (s)
IntelliFlex Switch
(Local/Sub-group/
Master Control)
To "Eye" Port
PSSW
(+75mA)
(+75mA)
(+75mA)
(-17 mA)
(-17 mA)
(-13 mA)
(-8 mA)
(-9 mA)
From "Aux"
To "Eye"*
Sun
Sensor
Eye
*Never connect "Eye" port
to "Eye" port
PC/
Home
Automation
IR Signal
to Eye
RF Signal
to Receiver
3
5
7
4
6
8
IntelliFlex Switch
(Local/Sub-group/
Master Control)
(-8 mA)
Comentários a estes Manuais