Isolating Relays
®
The isolating relay (ISO relay) prevents feedback between motors and allows multiple motors to run off a 120V switch. The switches that
Draper supplies are 15A so twelve standard motors are able to run off one switch with isolating relays. To further help you decide if isolating
relays are right for you, here are some conditions in which you would use them:
- You want to run multiple shades at one time, together off of one high voltage wall switch.
- You have parallel wired motors that you are trying to fi x.
- You want to remote locate controls in J-boxes by the shades to reduce wiring.
- You want the cheapest, most effective way to control up to twelve motors from one high voltage switch.
Isolating relays are not to be used if the following are your conditions.
- You are planning at any point and time to run the shades from a low voltage system such as AMX, Crestron, Vantage, etc.
- You want to operate a group of shades as two or more groups and together.
- You want to have preset intermediate stop action.
- You want to operate the shades from an IntelliFlex input device such as a sun sensor, IntelliFlex wall switch, IR remote, RF
remote, etc.
- You want the controls to come in an electrical enclosure.
- You want to upgrade the system at a later time to work from a computer or other low voltage switching device.
Page 35 of 120